Industrial ammonia refrigeration plants need pressure vessels for different refrigerant duties. Metalex builds both High Pressure and Low Pressure Vessels so project teams can match the vessel to the actual position, circulation method and operating requirement of the plant.

Both vessel types contribute to dependable refrigeration operation. The important step is to identify what the vessel needs to do within the system before deciding its capacity, orientation, connections and accessories.

Two Metalex vessel duties within one refrigeration system

High-side receiver duty

Metalex High Pressure Vessel

Supports liquid ammonia storage on the high-pressure side and helps accommodate refrigerant inventory through changing plant conditions and project-specific pump-down requirements.

Pumped circulation duty

Metalex Low Pressure Vessel

Supports low-pressure refrigerant collection, liquid-vapour separation and steady liquid supply to evaporators through refrigerant pumps.

A complete ammonia refrigeration plant may include both vessel types because they perform different but coordinated duties. Metalex presents them together within its industrial refrigeration pressure vessel range.

Metalex High Pressure Vessel

The Metalex High Pressure Vessel is used as a high-side refrigerant receiver. It stores liquid ammonia, supports refrigerant inventory management and can support pump-down requirements when included in the plant design.

Metalex offers horizontal and vertical configurations. The current product reference lists 15 kg/cm² working pressure, 30 kg/cm² test pressure and ASME or IS 2825 code reference. Final construction, capacity, orientation and connection schedule are aligned with the project specification.

Metalex Low Pressure Vessel

The Metalex Low Pressure Vessel supports pumped ammonia recirculation. It collects low-pressure refrigerant returning from evaporators, supports liquid-vapour separation and helps maintain liquid supply to the refrigerant pumps.

The current Metalex reference lists ammonia service, pumped feed, 6 kg/cm² working pressure and 21 kg/cm² test pressure. Gauge glass, floats, isolation valves, safety valve, drain and purge arrangements can be coordinated with the required vessel scope.

“The right vessel direction begins with its refrigeration duty, plant position and circulation method.”Metalex Engineering Note

Coordinating vessels with the complete plant

A pressure vessel works with the compressor, condenser, evaporators, refrigerant pumps, valves and controls. Metalex connects vessel manufacturing with wider refrigeration plant equipment and engineering support, helping project teams review the equipment as one coordinated system.

Suitable industrial refrigeration valves support isolation and refrigerant flow, while Metalex control panels bring monitoring and protection functions together according to the project requirement.

Information to share with Metalex

For a useful preliminary discussion, share the vessel duty, refrigerant, working and test pressure, capacity or dimensions, orientation, required connections, pump details where applicable, plant application and project location.

The Metalex engineering team can then review whether the requirement points to a High Pressure Vessel, a Low Pressure Vessel or both as part of the complete ammonia refrigeration system. The wider pressure vessel specification guide provides additional RFQ information for detailed project stages.